Electrical Megging Services

Megohmmeter insulation resistance testing for cables, conductors, motors, switchgear and transformers. Verify insulation integrity before you energize, during commissioning, and on a preventive maintenance schedule across Northern Virginia, DC and Maryland.

500V to 5kV DC testing Cables, motors and switchgear PI and DAR readings Documented test report De-energized and safe
Call (703) 880-8400
Plan the whole job Underground Cable Pullingthen Electrical Meggingthen Electrical Ground Testing
0 MΩ TEST LINE EARTH

What Is Electrical Megging?

Megging, or insulation resistance testing, uses a megohmmeter to apply a high DC test voltage between a conductor and ground and measure the resistance of its insulation, in megohms. High, stable resistance means healthy insulation. Low or declining readings reveal moisture, contamination or aging before they turn into a fault or an outage.

It is a core part of electrical acceptance and preventive maintenance work on commercial and industrial job sites across Fairfax County, Loudoun County, Washington, DC, and the Maryland suburbs. Data centers, hospitals and industrial facilities test insulation before they energize and on a set schedule so problems are caught while they are still cheap to fix.

  • Acceptance and commissioning testing of new feeders and cables
  • Preventive maintenance trending on critical circuits
  • Motor and transformer winding insulation tests
  • Troubleshooting suspected insulation faults
  • Verifying repairs before re-energizing
  • Polarization index (PI) and dielectric absorption ratio (DAR) tests

OTM handles the full test scope, from isolating and locking out the circuit to connecting the leads, running the test at the correct voltage, and documenting the results. We also serve Montgomery County and Prince George's County, MD.

Testing done right, documented, and safe.

You are not chasing a separate testing sub and hoping the paperwork shows up. One call, one crew that isolates the circuit, runs the test at the right voltage, and hands you a clean report.

Technicians who know switchgear and motors

Field crews who understand how cables, windings and switchgear behave, so the readings are set up and interpreted correctly.

The right test voltage for each asset

We match the test voltage to the rating of the equipment, from 250V control wiring up to 5,000V on medium-voltage gear.

Clear pass/fail documentation you can hand off

Readings, PI and DAR values, and a plain pass or fail for every item, ready for your commissioning package or maintenance file.

De-energized, locked out and tagged every time

The circuit is isolated and under lockout and tagout before any lead is connected. No live testing, no shortcuts.

250V-5kV
DC test range
PI + DAR
Trending readings
$2M
General liability
Same week
Scheduling

Electrical Megging FAQ

Megging is insulation resistance testing. A megohmmeter, often called a megger, applies a high DC test voltage between a conductor and ground and measures the resistance of the insulation in megohms. Higher, stable readings mean the insulation is healthy, while low or falling readings point to moisture, contamination or aging.

We select the test voltage for the rating of the equipment, typically 250V to 5,000V DC. Low-voltage control and building wiring is tested at the low end, while medium-voltage cable, switchgear and large motors call for higher voltages.

Higher and stable is better. Rather than a single hard number, we read the value against the equipment rating and its own history, and we use the polarization index (PI) and dielectric absorption ratio (DAR) to judge whether the insulation is drying and healthy or absorbing current and degrading. A downward trend over time is the real warning sign.

Yes. We test motor and transformer windings both winding-to-ground and winding-to-winding to check for moisture, contamination and insulation breakdown before the equipment is put back into service.

Yes. Megging is a de-energized test. The circuit or equipment is isolated and placed under lockout and tagout before any leads are connected, so the work is done safely with no live voltage present.

Yes. You get a documented test report with the readings, test voltage, PI and DAR values where applicable, and a clear pass or fail for each item tested, so it is ready to hand off to your commissioning package or maintenance records.

Request an Electrical Megging Quote

Tell us about your project and we will get back to you within 2 hours during business hours. Or call us directly:

(703) 880-8400
VA Class A Licensed
$2M General Liability
Same-Week Availability

Ready to Schedule Electrical Megging?

Call now or request a quote. We respond within 2 hours during business hours.

Call (703) 880-8400